Technical Specification
Parameter | PKN LC-4004U | PKN LC-10004U New! |
Channel number | 4 input / 4 output | |
Power requirements | 85V – 270VAC, 45 – 56 Hz or 85V – 270VDC* (400Vac proof**) | |
Max. Power consumption | 25 A | 50A |
Typical Mains requirement with music signal | 12A (110Vac), 6A (230Vac) “Fuse type-B” | 20A (110Vac) , 10A (230Vac) “Fuse type-B or C” |
Min. mains operational Voltage (prior UVLO activated) | 59Vac | |
Max. mains operational Voltage (prior OVLO activated) | 290Vac | |
Soft starting | yes, very soft power-up sequence | |
Power Supply | High frequency resonant includes active PFC | |
Mains power factor | > 0.94 (above 250W) | |
Mains connection | 25A Neutrik Powercon | 32A Neutrik Powercon |
Working temperature range | 0C – 45C | |
Storage temperature range | -25C – 60C | |
Maximum Peak Output Voltage (per channel) | 105Vp | 155Vp |
Output power @ 8 Ohms | 4 x 500W | 4 x 1200W |
Output power @ 6 Ohms | 4x 660W | 4 x 1600W |
Output power @ 4 Ohms | 4 x 1000W | 4 x 2100W |
Output Power @ 2.7 Ohms | 4x 1500W | 4 x 2700W |
Output power @ 2 Ohms | 4 x 1600W | 4 x 2600W |
Bridged power @ 8 Ohms | 2 x 2000W | 2 x 5000W |
Bridged power @ 4 Ohms | 2 x 3000W | 2 x 6000W |
Minimal load impedance | 2 Ohms | |
Frequency (+/- 3dB, 8 Ohms) | 5 Hz – 36 kHz | |
Slew rate (Input HF filter bypassed) | 50V / us | |
Damping factor ( 8?, range of 20Hz- 150Hz) | >2000 | >2500 |
Output Peak Current (per channel) | 44Ap | 56Ap |
End stages | PKN Improved fixed switching frequency Class D with true output feedback, reduced output HF carrier ripple circuitry | |
Output connection | Four pole Neutrik Speakon (1+2+ in parallel 1-2- parallel) | |
Effective sample rate per channel | 250KS/s | |
Gain ( Front knobs at 0dB) | 39dB | 42dB |
Signal to noise ratio | 104 dB | 106 dB |
Nominal sensitivity for max. output level (balanced) | 700 mV (rms) | |
Input impedance (referred to ground) | 10 kOhms + 10 KOhms ( +/- 1% ) | |
Input terminals | Neutrik XLR | |
Built in limiters | Max. output level, output current, signal no-clip, sustained high-frequency, intelligent over temperature | |
Crossover | Selectable fixed frequency 100 Hz HI-PASS filter, 120 Hz LO-PASS filter, 160 Hz LO-PASS filter | |
Output level meters | SIGNAL, AGR, PROTECTION, TEMP, READY LEDs | |
Protections | Short circuit, Overload, Low impedance, thermal, DC fault, High-frequency | |
Cooling | Forced air cooling with regulated, temperature dependent DC fans hidden in the case for reduced FAN noise level | |
Direction of air flow | Front to rear | |
Bridged configuration ability | yes | |
Remote | – | |
Weight | 9 Kgs | 11.6 Kgs |
External dimensions | 19″ rack 483 x 460 x 44mm (1RU) |